The WindSensor P2546-OPR Cup Anemometer combines unrivaled performance with the only IEC 61400-12-1 compliant classification on the market. Originally designed for marine environments, the P2546-OPR is ideally suited for wind resource assessment and power performance studies both onshore and offshore.
The P2546C-OPR (coil version) features permanent magnets mounted on the shaft that induce a voltage in a coil. This generates an sine wave output signal with a frequency proportional to the wind speed.
P2546-OPR features
Description |
|||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor type | 3-cup anemometer | ||||||||||||||||||
Applications | Wind resource assessment Wind turbine power performance measurement Meteorological and environmental monitoring |
||||||||||||||||||
Response characteristics |
|||||||||||||||||||
Calibration | Each anemometer individually calibrated compliant with IEC 61400-12-1 | ||||||||||||||||||
Calibration, mean value | U = 0.620 x f + 0.21 [m/s] | ||||||||||||||||||
Variation of calibrations | σ = 0.015 m/s @ 10 m/s | ||||||||||||||||||
Distance constant (63% recovery) | 1.81 ± 0.04 m | ||||||||||||||||||
Starting threshold | < 0.4 m/s | ||||||||||||||||||
Resolution | 0.001 m/s @ 10-minute average mode | ||||||||||||||||||
Range | 0...75 m/s | ||||||||||||||||||
Output signal |
|||||||||||||||||||
Signal type | Low-level AC sine wave, frequency proportional to wind speed | ||||||||||||||||||
Output voltage at 0.4 m/s | 25 mV peak, minimum | ||||||||||||||||||
Output voltage at 75 m/s | 14 V peak, typical | ||||||||||||||||||
Output resistance | 650 ± 50 Ω | ||||||||||||||||||
Accuracy |
|||||||||||||||||||
Calibration uncertainty, uV1, k=1 | 0.28 % @ 4…16 m/s | ||||||||||||||||||
Classification uncertainty, uV2, k=1 |
|
||||||||||||||||||
Power supply |
|||||||||||||||||||
P2546C-OPR | Self-excited, no external power supply required | ||||||||||||||||||
Environmental |
|||||||||||||||||||
Operating temperature range | -38...60 °C | ||||||||||||||||||
Operating humidity range | 0...100 % RH | ||||||||||||||||||
EMC compliance | EN61326-1 Class A | ||||||||||||||||||
Physical |
|||||||||||||||||||
Exterior materials | Anodized aluminum, Stainless steel and GRP | ||||||||||||||||||
Mating cable connector | Lemo E Series FFA.1E.650.CTAC45 (cable diameter 4.1…4.7 mm) | ||||||||||||||||||
Overall height | 282 mm | ||||||||||||||||||
Swept diameter of rotor | 188 mm | ||||||||||||||||||
Weight | 0.40 kg | ||||||||||||||||||
Shipping weight / dimensions | 1.15 kg / Cardboard box 360 x 230 x 210 mm | ||||||||||||||||||
Installation |
|||||||||||||||||||
Mounting | Onto a 25 ±0.1 mm (0.984 inch) diameter tube with two set screws | ||||||||||||||||||
Tools required | 4 mm Allen wrench (enclosed) | ||||||||||||||||||
Specifications documents
Application notes
Compliance
External documentation
RNRG Symphonie dataloggers - P2546-OPR Anemometer Wiring and Installation Information